Product use

This machine is suitable for determining the shear rate of plastics and polymer materials under certain temperature conditions, the fluidity of the melt under shear stress, including the apparent viscosity of thermoplastics.

  • Product description

I.   Technical Parameters

1.  Temperature range: room temperature~400 ℃

2.  Heating rate: 1-10 ℃/min, continuously adjustable, and capable of rapid heating

3.  Temperature measurement accuracy: 0.1 ℃

4.  Pressure range: 1-50MPa ± 0.5%

5.  Plug diameter: Ø 12mm

6.  Power supply: 1∮, AC220V, 50Hz

7.  Plug area: 113.04mm ²

8.  Speed range: 0.01-500mm/min

9.  Dimension: 650 x 450 x 1650 (W x D x H) mm

10.Maximum driving force: 5KN

11.Pressure resolution: 0.1MPa

12.Specification of discharge port mold: Ø1x5, Ø1x10, Ø1x20, Ø1x40mm

13.Material of discharge port mold: tungsten carbide

14.Pressure measurement accuracy: ± 0.5% FS

15.Deformation measurement accuracy: ± 0.5% FS

 

II.  Main configuration

1.  Main machine  1 unit

2.  Japan high precision temperature control detection system  1 set

3.  Japan Fuji servo controller  1 pcs

4.  Japan Fuji Electric  1 pcs

5.  Limit system for displacement stroke  1 set

6.  Displacement detection system  1 set

7.  High precision pressure detection system  1 set

8.  Branded computers  1 set

 

III. Test items

1.  Constant speed shear test: measure shear stress and shear rate curves, shear viscosity and shear rate curves

2.  Constant pressure shear test: measure the shear viscosity and shear rate curve

3.  Step shear rate test: Different shear rates can be set according to user requirements, and shear stress and

     shear rate curves, shear viscosity and shear rate curves can be measured. During the experiment, the

     fracture of the melt and the minimum flow pressure and shear rate of the melt can be determined based

     on the changes in the curves

a)  Flow/non flow testing: measuring the relationship between viscosity and temperature, accurately

     determining the minimum flow velocity

b)  Melt fracture and flow instability: Study of flow instability phenomena, including melt fracture and melt

     cracking

Previous:BP-8187-B-III2024-05-10
Next:BP-8189-B2024-05-10

Recently Viewed:

Related news

Online evaluation (0)

    No evaluation information!

  • menu
  • 1

Copyright Statement: The text, images, and related "BAOPIN" logo on this website are owned by Dongguan Baopin Precision Instrument Co., Ltd, Without the permission of the rights holder, no unit or individual is allowed to reprint or steal. Those who infringe on their legitimate rights will be held legally responsible.

    Address: No. 29, Houjie Section, Gangkou Avenue, Houjie Town, Dongguan City, Guangdong Province     

          Telephone: 0769-85752595/0769-85759676/0769-85759987   Technical Support: Haichuan Technology

E-Mail: bp@dgbaopin.com/msnzhzhao@sina.com        Record No.: Guangdong ICP No. 17002540